Zone 1 vs Zone 2 Explosion-Proof Lighting: What Changes and What It Costs

Zone 2 and Zone 1 hazardous area lighting compared: which protection types and EPLs each zone accepts, why Zone 1 fittings cost more, a Zone 2 pump-house layout, and how to light mixed sites.

Key points

  • Zone 1: an explosive gas atmosphere is likely to occur in normal operation, occasionally. Zone 2: it is not likely, and if it occurs, only for a short time.
  • Zone 1 needs equipment protection level Gb (or Ga), typically flameproof Ex db or increased safety Ex eb fittings. Zone 2 accepts Gc, for example Ex ec, as well as anything rated for Zone 1.
  • A Zone 1 fitting may be used in Zone 2, never the other way round. Using one Zone 1 type across a mixed site simplifies spares, at a higher price and weight per fitting.
  • The zone, gas group and temperature class come from the site's area classification drawing, not from the lighting supplier.
  • By our lighting calculator, a 12 × 8 m Zone 2 pump house at 150 lux needs 6 fittings of 60 W, whichever zone type is chosen; the zone changes the fitting, not the count.

On a refinery, chemical plant, paint shop or fuel depot, the lighting layout follows the hazardous area drawing. Most of the site is usually Zone 2, with smaller Zone 1 areas around pumps, vents, filling points and inside enclosures. Choosing between Zone 1 and Zone 2 fittings, area by area, is where much of the cost of hazardous area lighting is decided.

If you work under the North American Class/Division system, our separate guide to Class 1 Division 2 lighting covers C1D2 fixtures, their markings and how they map to Zone 2. This article stays with the IEC Zone system.

Zone 2 hazardous area lighting in one paragraph

Zone 2 is the most common hazardous area on most process sites. Lights there need equipment protection level Gc or better: a Zone 2 fitting such as Ex ec, or any Zone 1 fitting (Ex db, Ex eb, Ex mb). The gas group (IIA, IIB or IIC) and temperature class must also suit the gases on the drawing. Because Zone 2 fittings only have to avoid sparks and hot surfaces in normal operation, they can be lighter and cheaper than flameproof Zone 1 fittings, but many sites still use one Zone 1 type everywhere to keep spares simple.

What the zones mean

Hazardous areas for gases and vapours are classified by how often an explosive atmosphere is present (IEC 60079-10-1):

Zone Explosive gas atmosphere Typical guidance (hours per year) Required EPL
Zone 0 Present continuously or for long periods more than about 1,000 h Ga
Zone 1 Likely to occur occasionally in normal operation about 10–1,000 h Gb (or Ga)
Zone 2 Not likely in normal operation; if it occurs, only briefly less than about 10 h Gc (or Gb, Ga)

Dust areas follow the same pattern as Zones 20, 21 and 22, with EPLs Da, Db and Dc. The hours are a rule of thumb used in practice, not part of the definition. For what EPL, gas group and temperature class mean in a marking, see explosion proof lighting explained.

Typical examples

  • Zone 1: close to pump seals, sampling points, vents and filling connections; inside spray booths and some mixing rooms; pits and trenches where heavy vapours collect
  • Zone 2: the wider process area around Zone 1; around flanges and valves that only leak on failure; tank farm bunds; well-ventilated rooms with closed systems
  • Lighting is rarely installed in Zone 0, which is usually inside tanks and vessels

The classification is made by the site’s process safety engineers and recorded on an area classification drawing. The lighting supplier works from it.

Protection types for each zone

Protection type Code EPL Allowed in
Flameproof enclosure Ex db Gb Zone 1 and 2
Increased safety Ex eb Gb Zone 1 and 2
Encapsulation Ex mb Gb Zone 1 and 2
Increased safety, Zone 2 level Ex ec Gc Zone 2 only
Non-sparking (older marking) Ex nA Gc Zone 2 only
Dust protection by enclosure Ex tb / Ex tc Db / Dc Zone 21 and 22 / Zone 22

Many LED fittings combine types: for example, a flameproof (db) driver chamber, increased safety (eb) terminal box and encapsulated (mb) parts, all at Gb level.

Why Zone 1 fittings cost more

A flameproof (Ex db) enclosure must contain an internal explosion and cool the escaping gases through precisely machined flame paths. That means thick cast aluminium or stainless steel, heavy glass, and certified cable glands. A Zone 2 fitting (Ex ec) instead prevents sparks and hot surfaces in normal operation, which allows a lighter housing.

In practice, compared with a Zone 2 fitting of similar light output, a Zone 1 flameproof fitting is typically:

  • Heavier, which affects brackets, poles and handling at height
  • More expensive, often substantially so
  • Slower to maintain, because flame paths and glands must be inspected and kept in order

That is why it pays to use Zone 2 fittings where the drawing allows, and Zone 1 fittings only where they are needed.

The case for one type across the site

There is also a good argument for standardising on one Zone 1 fitting for a whole site with mixed zones:

  • One type of spare part, one installation method, one inspection procedure
  • No risk of a Zone 2 fitting being moved into Zone 1 during maintenance or a layout change
  • Future changes to the area classification do not force a lighting change
  • Easier procurement of fewer, larger batches

For a small site, or a plant where Zone 1 makes up a large part of the area, standardising usually wins. For a large plant with mostly Zone 2, the savings of Zone 2 fittings across hundreds of lights are worth the extra spare-parts management.

The other parts of the selection

The zone is only one of four checks. The fitting must also match:

  1. Gas group: IIA (e.g. propane), IIB (e.g. ethylene) or IIC (hydrogen, acetylene). IIC covers IIB and IIA
  2. Temperature class: T1 (450 °C) to T6 (85 °C); the fitting’s class must be below the auto-ignition temperature of the gases present
  3. Ambient temperature range: many fittings are certified for −20 to +40 °C; hot plants need a higher rating
  4. Certification scheme accepted in your country: IECEx, ATEX, a national scheme such as China’s GB 3836 (CCC), or Class/Division for North America

Our explosion proof LED lights buying guide covers the electrical and mechanical details, and explosion proof lighting for paint booths is a worked example of a Zone 1 area.

Worked example: a Zone 2 pump house

Take a pump house 12 × 8 m, lights at 4.5 m, classified Zone 2 with a IIA gas and a target of 150 lux. With our BDE507 at 60 W and 110 lm/W, our lighting calculator gives 6 fittings (3 × 2) at 4.0 m spacing and about 187 lux, with 3.75 W/m².

The count would be the same with a Zone 2 fitting of the same light output. What the zone changes is the fitting: its weight, price and inspection routine. If two pumps in the room have seals classified as small Zone 1 areas, either keep the fittings out of those areas or use a Zone 1 type for the whole room. The BDE507 is marked Ex d IIC T6 Gb, so it suits both zones; its certificate is supplied with the quotation.

Planning lighting for a mixed site

  1. Get the area classification drawing with zones, gas groups and temperature classes
  2. Mark the lighting points on it and note the zone at each one
  3. Decide the strategy: Zone 1 type throughout, or Zone 1 and Zone 2 types by area
  4. Check the light levels for each area (walkways, pump areas, loading bays); the wattage logic is the same as for ordinary lighting
  5. Plan emergency lighting in hazardous areas, which also needs certified fittings
  6. Keep the certificates and installation records in the site’s hazardous area dossier for inspection

Our explosion-proof lights

Our BED series explosion-proof LED light (30–600 W) is certified Ex db eb mb IIC T4 Gb and Ex tb IIIC T130 °C Db under GB 3836, for Zone 1 and Zone 2 gas areas including hydrogen and acetylene, and Zone 21 and 22 dust areas. For our other explosion-proof series, the certificate for the exact model is supplied with the quotation. Send us the area classification, gas group, temperature class and the certification scheme your project requires, and we will confirm which fittings and certificates match.

Sources

  1. IEC 60079-10-1 — Explosive atmospheres: Classification of areas, explosive gas atmospheres (IEC webstore)
  2. IECEx — International certification scheme for equipment for explosive atmospheres

Frequently asked questions

What is the difference between Zone 1 and Zone 2?

In a Zone 1 area, an explosive gas atmosphere is likely to occur occasionally in normal operation. In a Zone 2 area, it is not likely in normal operation and, if it does occur, will last only a short time. Zone 1 therefore needs equipment with a higher protection level (Gb) than Zone 2 (Gc).

Can Zone 1 lights be used in Zone 2?

Yes. Equipment certified for Zone 1 (EPL Gb) may be used in Zone 2, provided the gas group and temperature class also suit the site. Equipment certified only for Zone 2 (EPL Gc) must not be used in Zone 1.

What lights can be used in a Zone 2 hazardous area?

Any fitting with equipment protection level Gc or better and a gas group and temperature class that suit the site: Ex ec or the older Ex nA fittings, and all Zone 1 types such as Ex db and Ex eb. The fitting must be certified under a scheme the site accepts.

Is Class I Division 2 the same as Zone 2?

Roughly. Class I Division 2 in the North American system corresponds closely to Zone 2, while Class I Division 1 covers both Zone 0 and Zone 1. The marking and certification schemes differ, so check which system the site uses.

Products in this guide

Have a project?

Ask our engineers

Send us your site details and we will size the system and quote it.

We reply by email within one working day (China time, GMT+8). Your details are only used to answer this inquiry. Prefer chat? Message us on WhatsApp. Have more detail to give? Use the full form.

Related guides