Get a quote

Recessed LED Linear Lights: Sizes, Output per Metre and Layouts for Offices

How recessed LED linear lights compare with troffers and panels, how to size output per metre for continuous lines, and worked office and corridor layouts from our calculator.

Key points

  • Recessed linear lights sit flush in plasterboard or grid ceilings as single runs or continuous lines; they suit offices, corridors and retail where a clean ceiling matters.
  • In our calculator, a 12 × 8 m office with a 2.7 m ceiling reaches about 576 lux with thirty 36 W linear fittings at 90 lm/W, or about 512 lux with forty 24 W fittings.
  • For continuous lines, size by watts per metre: five 12 m lines in that office need only about 16 W per metre for 500 lux.
  • Recessed linear lights need ceiling cut-outs, access for drivers and a fire-rating check; troffers and panels are simpler in standard grid ceilings.

Recessed LED linear lights are the long, slim slots of light you see in modern offices, airport corridors and shops. Compared with square panels, they draw clean lines on the ceiling, line up with desks and walls, and can run unbroken from one end of a room to the other. They also bring questions that panels do not: how much output per metre, how far apart the lines should be, and what the ceiling needs to accept them. This guide answers those with worked layouts from our calculator.

What counts as a recessed linear light

A recessed linear light is a narrow luminaire, usually 35–100 mm wide, set into the ceiling so that only the diffuser shows. Three forms are common:

  • Single units of 600, 1,200 or 1,500 mm, used like a slim troffer.
  • Continuous lines, joined end to end with connectors, running the full length of a room.
  • Trimless versions, plastered in so that no frame is visible.

They are made for plasterboard ceilings, grid ceilings (with a matching width) and some metal ceilings. Suspended and surface-mounted linear lights use the same light engine but hang below or sit on the ceiling; our hanging LED commercial light fixtures guide covers them.

Linear, troffer or panel?

Feature Recessed linear Grille troffer Flat panel
Ceiling Plasterboard or grid Grid Grid or surface frame
Look Lines, architectural Traditional louvre Even square of light
Layout freedom High Grid only Grid only
Installation Cut-outs, more labour Drop into grid Drop into grid
Typical use Offices, corridors, retail Offices, schools, hospitals Offices, classrooms

For a standard 600 mm grid ceiling, panels and troffers are faster and cheaper. Our LED troffer lights and LED flat panel light guides cover them. Linear lights earn their extra labour where appearance and alignment matter.

Our relevant products

Model Type Power Efficacy Size
BG-TXH Linear, suspended or surface 24 / 36 / 60 W 90 lm/W 1,200 mm long
BG-DPT8A Recessed grille troffer 27 / 36 W 90 lm/W 600 × 600 / 1,200 × 600 mm
BG-MBC Flat panel 12–48 W 90 lm/W Several sizes

The BG-TXH is not a recessed fitting; we list it because its light engine data (36 W, 90 lm/W, 120° beam) is a fair stand-in for a typical recessed linear unit in the calculations below. For flush grid ceilings, the troffer and panel are the recessed options we supply.

Worked example: a 12 × 8 m office

An open office, 12 × 8 m, ceiling at 2.7 m, desks at 0.8 m, light-coloured walls, target 500 lux. Using our high bay lighting calculator, which handles any room size:

36 W linear units at 90 lm/W (open the example):

  • 30 fittings, 6 along × 5 across, at 2.0 × 1.6 m;
  • about 576 lux average, 11.3 W per m².

24 W linear units at 90 lm/W (open the example):

  • 40 fittings, 8 along × 5 across, at 1.5 × 1.6 m;
  • about 512 lux average, 10 W per m².

With 1.2 m units at 1.5 m pitch, the 24 W option leaves only 0.3 m gaps in each row, so it is very close to a continuous line already.

Sizing continuous lines by watts per metre

For continuous lines, think in watts per metre rather than fittings. In the office above, five lines run the full 12 m, so there are 60 m of line in total.

The calculator reports that about 31 W per fitting would just meet 500 lux in the 30-fitting layout, so the room needs about 30 × 31 ≈ 940 W of light at 90 lm/W. Spread over 60 m:

940 W ÷ 60 m ≈ 16 W per metre

So a continuous recessed line rated around 15–20 W per metre at 90 lm/W, or 12–16 W per metre at 110 lm/W, lights this office properly. Running 1.2 m units of 36 W end to end would give 30 W per metre, nearly double, and the room would be over-lit and glary unless dimmed.

Corridors

A corridor 30 m long and 2 m wide with a 2.7 m ceiling, lit to 100 lux at floor level with 24 W units (open the example):

  • 12 fittings in one line, 2.5 m apart;
  • about 146 lux average.

The calculator says 16 W per fitting would be enough. A single line of lower-output units, or 24 W units dimmed to about 70 %, is the efficient answer. See LED panel lights for corridors for the panel alternative.

Glare and comfort

Linear lights look elegant but can be harsh if the diffuser is bright. Points to check:

  • Diffuser type. Opal diffusers spread the light; microprismatic diffusers control glare better for screen work.
  • Unified glare rating. Offices usually target UGR 19 or lower. Ask for the UGR table for your room size.
  • Line direction. Run lines parallel to the main line of sight or along desk rows, not across screens.

Ceiling and installation points

  • Cut-out accuracy. Recessed linear lights need straight, accurate cut-outs. Plan them on the reflected ceiling plan before the boards go up.
  • Driver access. Drivers sit above the ceiling; make sure they can be reached through the fitting or an access panel.
  • Fire rating. Cutting a fire-rated ceiling may need fire hoods or rated fittings. Check with the fire engineer.
  • Joining lines. Use the maker’s connectors so the joins stay straight and light-tight.

Controls

Dimmable drivers (0–10 V or DALI) let you trim over-lit layouts and add daylight and presence control. Our commercial lighting control systems guide explains the options, and dimmable LED panel lights covers dimming drivers in more detail.

What to send us

The reflected ceiling plan or room sizes, ceiling type and height, target lux and any UGR or dimming requirements. We will reply with a layout from our calculator and say clearly which of our fittings fit your ceiling.

Sources

  1. EN 12464-1 — Lighting of work places, Part 1: Indoor work places
  2. IES RP-1 — Recommended Practice for Lighting Office Spaces
  3. BlueGreen OE — BG-TXH LED linear light
  4. BlueGreen OE — BG-DPT8A grille troffer and BG-MBC panel product data

Frequently asked questions

What is a recessed LED linear light?

A long, narrow LED fitting installed into the ceiling so that its diffuser sits flush with the ceiling surface. It can be used as separate units or joined end to end into continuous lines.

How many watts per metre does a recessed linear light need?

For general office lighting at about 500 lux with lines 2–2.5 m apart, typically 12–20 W per metre at 90–110 lm/W. Corridors need less, retail accents more.

Recessed linear or 600 × 600 panel for an office?

Panels are simpler in a standard grid ceiling. Linear lights give a more architectural look, line up with desks and walls, and work in plasterboard ceilings where a grid is not wanted.

Can linear lights be dimmed?

Yes, with a dimmable driver: 0–10 V and DALI are common in offices. Choose the dimming method at the order stage because it changes the driver.

Does your linear light come in a recessed version?

Our BG-TXH is a suspended and surface linear light. For recessed grid ceilings we supply the BG-DPT8A grille troffer and BG-MBC panels. Tell us your ceiling type and we will say what we can supply.

Products in this guide

Have a project?

Ask our engineers

Send us your site details and we will size the system and quote it.

We reply by email within one working day (China time, GMT+8). Your details are only used to answer this inquiry. Prefer chat? Message us on WhatsApp. Have more detail to give? Use the full form.