Hanging LED Commercial Light Fixtures: Linear Pendants for Offices and Shops

How to choose and lay out hanging LED commercial light fixtures (linear pendants) for offices and shops: suspension height, spacing, glare, and two worked layouts from our calculator.

Key points

  • Hanging linear pendants suit offices, shops, schools and showrooms with ceilings from about 3 m up, especially exposed or open ceilings where recessed lights cannot go.
  • Hang the fixtures so the light sits about 2.6–2.8 m above the floor in a 3–3.5 m room, and keep rows within about 1.5 times the distance to the desk or counter.
  • In our calculator a 16 × 10 m office reaches about 413 lux with 35 × 36 W BG-TXH pendants; a 20 × 10 m shop reaches about 502 lux with 32 × 60 W.
  • Align the rows with desks, counters or shelving and run them parallel to windows; glare and shadows usually come from layouts, not from the fixture.

Hanging fixtures have moved from warehouses into offices, shops and restaurants. Open ceilings, exposed concrete and tall retail spaces suit them, and a straight line of light reads as a design element as well as a source. This guide covers the decisions that make a pendant layout work: height, spacing, alignment and glare. Then it runs two layouts through our calculator with our own linear pendant.

Where hanging fixtures make sense

  • Open or exposed ceilings: no ceiling grid for recessed panels.
  • High rooms (3.5 m and up): pendants bring the light down to a useful height.
  • Spaces that need a visible line: shops, showrooms, cafés, reception areas.
  • Retrofits: where the ceiling cannot be opened, pendants hang from existing points.

In a standard 2.7 m grid ceiling, recessed panels are usually simpler; see our LED flat panel light guide. For tall industrial spaces, high bay pendant lighting covers heavier fittings.

Our linear pendant

The BG-TXH is a 1.2 m aluminium and acrylic linear pendant:

Model Power Size Luminous flux at 90 lm/W
BG-TXH24 24 W 1200 × 100 × 60 mm about 2,160 lm
BG-TXH36 36 W 1200 × 200 × 60 mm about 3,240 lm
BG-TXH60 60 W 1200 × 300 × 60 mm about 5,400 lm

It runs on AC 100–240 V, with 3000–6000 K, CRI Ra 70–90 and a 120° beam.

Height

Two distances matter: the height of the fixture above the floor, and its height above the working plane (desks at about 0.8 m, shop counters at about 0.9 m). In a room with a 3–3.5 m ceiling, a fixture at 2.6–2.8 m above the floor is a good default:

  • low enough to put light on desks and shelves efficiently;
  • high enough that people walking or sitting do not look straight into the diffuser;
  • clear of door heads and tall shelving.

Spacing and alignment

For a wide 120° beam, keep fixtures within about 1.5 times their height above the working plane. Our calculator applies this limit automatically.

Then align the layout with the room:

  • Offices: rows parallel to the windows and running alongside desks, not directly over screens. This reduces reflections on monitors.
  • Shops: rows over the aisles in front of shelving, so the vertical faces of products are lit, not just the floor.
  • Counters and tables: one line centred over each counter or long table.

Worked example 1: an open-plan office

A 16 × 10 m office, 3.2 m ceiling, pendants at 3.0 m measured from the floor in the calculator’s height field, light-coloured surfaces, 400 lux target on desks, BG-TXH36. Our high bay and indoor lighting calculator gives (open the example):

  • 35 fixtures in a 7 × 5 grid, 2.3 × 2.0 m apart;
  • about 413 lux average;
  • 7.9 W per m².

To reach the 500 lux EN 12464-1 asks for at desks, keep the same rows and use the 60 W model over the desk zones, or add desk lamps. Walkways and storage areas can stay at the 36 W level.

Worked example 2: a shop floor

A 20 × 10 m shop, pendants at 3.2 m, light surfaces, 500 lux, BG-TXH60 (open the example):

  • 32 fixtures in an 8 × 4 grid, 2.5 m apart;
  • about 502 lux average;
  • 9.6 W per m².

In practice, set the four rows over the aisles in front of the shelving rather than on a uniform grid. The count stays the same and more light lands on the merchandise.

Glare and comfort

  • Diffuser brightness: an opal acrylic diffuser like the BG-TXH spreads the light, but a fixture hung too low can still be uncomfortable. Our UGR glare rating guide explains how glare is measured.
  • Colour temperature: 4000 K is the common office choice; 3000 K suits cafés and shops that want a warmer look.
  • CRI: Ra 80 or higher for retail, where colour matters.

Controls

Pendants along the window side can be switched or dimmed separately to use daylight. Occupancy sensors suit meeting rooms and storage. See our guide to commercial lighting control systems.

Installation points

  • Use the suspension kit supplied, fixed to the structure, not to ceiling tiles.
  • Level each fixture; uneven pendants are very visible in a line.
  • Plan cable drops so the feed cable runs neatly alongside one suspension wire.
  • Keep the same model and colour temperature across a room; mixing batches shows.

Common mistakes

  • Hanging every fixture at the same drop in a sloping ceiling. Measure from the floor, not the ceiling, so the light line stays level.
  • Rows running across desks. People then sit with a bright line directly in front of or behind their screens.
  • Ignoring emergency lighting. Pendants with emergency battery packs, or separate emergency fittings, are still needed on escape routes.
  • Planning the grid before the furniture. Get the desk or shelving plan first; the row positions follow from it.

What to send us

The room plan, ceiling height, desk or shelf layout, target lux and preferred colour temperature. We will run the layout in our calculator and suggest the model and row positions.

Sources

  1. EN 12464-1 — Lighting of work places: Indoor work places
  2. IES RP-1 — Recommended practice: Lighting for offices
  3. BlueGreen OE — BG-TXH LED linear pendant light

Frequently asked questions

How high should hanging commercial lights be?

In a typical office or shop with a 3–3.5 m ceiling, hang linear pendants so the fixture is about 2.6–2.8 m above the floor. Lower than about 2.4 m and people start to see the bright diffuser directly; higher and the spacing must shrink.

How far apart should linear pendant rows be?

Keep rows within about 1.5 times the height of the fixture above the desk or counter. For pendants 2 m above a desk, that means rows no more than about 3 m apart.

How much light does an office need?

EN 12464-1 asks for 500 lux on desks for writing, reading and computer work, with lower levels allowed in surrounding areas. Many offices design for 300–500 lux depending on tasks and local codes.

Can linear pendants be connected in a continuous line?

Many designs can, which gives a clean look in long rooms. Check whether the model supports through-wiring and joiners before planning continuous runs.