Get a quote

Office Light Fixtures: LED Office Lighting Levels, Layouts and Fixture Types

How to light an office with LED: lux levels by task, panels, linear pendants, downlights and track lights, a worked open-office layout, glare and flicker, and controls that cut energy use.

Key points

  • Typical targets: 500 lux on desks, 300 lux in general areas, 100–200 lux in corridors, with UGR 19 or lower where people use screens.
  • A 20 × 12 m open office at 500 lux needs about 70 panels of 36 W at 90 lm/W, or about 54 at 117 lm/W: efficacy changes the count by a quarter.
  • Mix fixture types by zone: panels or pendants over desks, downlights in meeting rooms and corridors, track lights for display walls.
  • Daylight dimming, occupancy sensors and zoning usually cut office lighting energy by a further 30–50% after the LED upgrade.

Offices are where lighting is used for the longest hours by the most people, and where poor lighting is most noticed: glare on screens, dark corners, flicker and headaches. LED solves the energy side easily. Getting comfortable light takes a few more decisions about levels, fixture types and controls.

Light levels

From EN 12464-1 and comparable standards:

Area Maintained illuminance UGR limit CRI
Writing, reading, screen work 500 lux 19 80
Technical drawing 750 lux 16 80
Meeting rooms 500 lux 19 80
Reception desks 300 lux 22 80
Archives, filing 200 lux 25 80
Corridors 100 lux 28 40
Toilets 200 lux 25 80

The 2021 edition also recommends light on walls and ceilings, not only on the desk, so rooms do not feel like a dark box with bright pools.

Fixture types for offices

Fixture Where Notes
Recessed panels Open offices with suspended ceilings Even light; choose low-glare versions for screens
Linear pendants Open ceilings, modern offices Up and down light; good for walls and ceilings
Downlights Meeting rooms, corridors, reception Accent and general light
Track lights Display walls, showrooms, receptions Adjustable
Surface ceiling lights Small offices, toilets, stores Easy installation
Linear tubes Back-of-house, stores, car parks Low cost

Our range for offices includes LED panel lights (12–48 W, 90 lm/W), the low-glare office panel, linear pendant lights, downlights and track lights.

A worked example: open office

An open office of 20 × 12 m, 3 m ceiling, light finishes, desks at 0.8 m, target 500 lux. With 36 W panels at 90 lm/W (about 3,240 lm each), the lumen method in our lighting calculator gives:

Lighting calculator result for a 20 by 12 m open office with 36 W LED panels at 500 lux
A 20 × 12 m open office at 500 lux: 70 panels of 36 W at 90 lm/W, in a 10 × 7 grid.
  • 70 panels in a 10 × 7 grid, about 572 lux average
  • 10.5 W/m² lighting power density

Open this example and enter your own room.

Two ways to change the result:

Option Panels Power density
36 W at 90 lm/W 70 10.5 W/m²
48 W at 90 lm/W 54 10.8 W/m²
36 W at about 117 lm/W 54 8.1 W/m²
Same room at 300 lux (general area), 36 W at 90 lm/W 40 6.0 W/m²

Higher efficacy cuts the fixture count by about a quarter for the same light. Fewer, more powerful panels save fittings and installation but not energy, and they space further apart, which can reduce uniformity.

Glare, flicker and comfort

  • UGR 19 or lower for desks with screens. Panels with micro-prismatic diffusers, louvred fittings and pendants with shielded down-light help.
  • Flicker: specify flicker-free drivers (low percent flicker). Flicker is invisible but can cause headaches and shows on cameras and video calls.
  • Colour temperature: 4000K is the usual office choice; 3000K for lounges and hospitality areas.
  • Colour rendering: Ra 80 minimum; Ra 90 where colour matters (design studios).
  • Walls and ceilings: pendants with an up-light component and wall-washing downlights make rooms feel brighter at the same desk lux.

Layout tips

  1. Align rows parallel to windows so rows can be dimmed with daylight.
  2. Keep fixtures off directly above screens’ reflection zones, or use low-glare optics.
  3. Plan for desk changes: an even grid copes better than lights placed over today’s desks.
  4. Light meeting room tables and walls separately so presentations work with some lights dimmed.
  5. Corridors: a line of downlights or linear fittings at 100–200 lux, on occupancy sensors.

Controls

Control Typical saving Where
Occupancy / absence sensors 20–40% Meeting rooms, toilets, stores, corridors
Daylight dimming 20–40% near windows Rows within about 4–5 m of windows
Time scheduling 10–20% Whole floors after hours
Task tuning (setting maximum output) 10–20% Over-lit new installations

Dimming needs compatible drivers: 0–10 V or DALI for networked control, or fixtures with integrated sensors.

Upgrading an existing office

Replacing fluorescent troffers with LED panels is usually the biggest single saving. A 600 × 600 fitting with four 18 W T8 tubes uses about 70–80 W with its ballast; a 36 W LED panel replaces it. Before ordering:

  • Check the ceiling grid size (600 × 600 mm or 2 × 2 ft)
  • Note which rooms are over- or under-lit today
  • Decide whether to add sensors and dimming at the same time, since the ceiling is open anyway

Choosing between panels and pendants

Panels suit offices with suspended ceilings and a need for low cost per square metre. Linear pendants suit open ceilings with exposed services, where they hide cable trays and add up-light to the ceiling. Pendants also make it easier to follow desk rows and give a more architectural look in receptions and meeting spaces. Many modern offices combine both: panels in work zones, pendants over collaboration areas and downlights in corridors.

Emergency lighting

Escape routes, stairs and exits need emergency lighting that works during a power cut, often for 90 minutes or more depending on local rules. Many panels and downlights can be supplied with emergency packs, and exits need signs; see our LED exit signs.

What to send for a quotation

Floor plans with ceiling types and heights, the use of each area, any glare or design requirements, and whether you want controls. We will propose fixtures, a layout and the expected lux and power density for each area.

Sources

  1. EN 12464-1:2021 Light and lighting — Lighting of work places — Indoor work places
  2. BlueGreen OE — High bay lighting calculator (lumen method)

Frequently asked questions

How many lux does an office need?

About 500 lux on desks for writing, reading and screen work, 300 lux in general circulation and filing areas, 100–200 lux in corridors and 500 lux in meeting rooms, following EN 12464-1 and similar standards.

What is the best lighting for an office?

Low-glare LED fixtures (UGR 19 or less) at 4000K with Ra 80 or higher, giving even light on desks and some light on walls and ceilings, with flicker-free drivers and controls for daylight and occupancy.

How many LED panels do I need for an office?

Use the lumen method: target lux × floor area ÷ (lumens per panel × utilisation factor × maintenance factor). For example, an 8 × 6 m office at 500 lux needs about 12 panels of 36 W at 117 lm/W, or about 16 at 90 lm/W.

Have a project?

Ask our engineers

Send us your site details and we will size the system and quote it.

We reply by email within one working day (China time, GMT+8). Your details are only used to answer this inquiry. Prefer chat? Message us on WhatsApp. Have more detail to give? Use the full form.