Replacing High Pressure Sodium Lights with LED: A Road Retrofit, Step by Step
High pressure sodium LED replacement: bulb, retrofit kit or new head, the LED wattage that replaces 250 W and 400 W HPS at the old spacing, savings and a 13 km example.
Key points
- Choose the LED wattage from the road's lighting class at the existing pole spacing, not from the old lamp wattage.
- On a 15 m wide road with 12 m poles at 42 m, our spacing calculator shows about 132 W of LED meets M3 and about 194 W meets M2, where 400 W sodium lamps used to burn.
- For 624 lights changed from 400 W HPS (460 W with ballast) to 150 W LED, the retrofit calculator gives about 847,000 kWh saved a year, 67% of the old energy use.
- Survey poles, arms, cables and photocells first; most retrofits reuse them, and the survey decides the bracket and the driver options.
Most high pressure sodium (HPS) street lighting still in service was designed around the lamp: 250 W here, 400 W there, poles spaced to suit. Replacing it with LED is not a lamp swap. It is a small redesign that keeps the poles and cables and changes what sits on top. Done that way, the saving is large and the road ends up better lit, not just cheaper to run.
Our own example is close to home: in 2020 the main road and service roads along 13 km of Tanzhou Avenue in Xiangtan were converted from sodium to our LED street lights. The steps below are the ones a retrofit of that kind goes through. The numbers are a worked example for a similar road, not the project’s own specification.
High pressure sodium LED replacement: bulb, kit or new head?
Short answer: on a road, replace the whole head. An LED “corn” bulb in the old lantern is the cheapest way to convert high pressure sodium to LED, but it keeps the old optic, so much of its light misses the road and the bulb runs hot inside a fitting designed for a sodium lamp. A retrofit kit is a middle path. A new LED head on the existing arm gives the best light per watt and the longest life.
| Route | What changes | Ballast | Typical use |
|---|---|---|---|
| LED bulb in old lantern | Lamp only | Bypassed and rewired | Short-term fix, few lights |
| Retrofit kit | LED module and driver inside old housing | Removed | Decorative lanterns worth keeping |
| New LED head | Whole luminaire, same arm | Removed with old head | Most road retrofits |
How much LED replaces the sodium lamp also depends on the road, not the lamp. A worked example for a common case: a 250 W HPS lantern on a 10 m pole, 7 m two-lane road, poles 35 m apart on one side. In our pole height and spacing calculator (open the example), a 100 W LED head at 110 lm/W gives about 15.5 lux at that spacing, enough for class M3; the calculator reports that about 97 W would just meet it. So a 250 W sodium lamp, which draws close to 290 W with its ballast, is replaced by 100 W of LED: about a 65 % cut at the same spacing. Our HPS to LED conversion wattage chart lists other lamp sizes, and LED street light bulb vs fixture compares the bulb route in detail.
The rest of this guide follows the new-head route on a larger road.
Step 1: Survey what is already there
Before choosing a single luminaire, walk the road and record:
- Pole height, spacing and layout (single side, staggered, opposite, central twin-arm)
- Arm length, tilt and spigot diameter: the LED head must fit the arm, usually 42–60 mm
- Pole condition at ground level and at the door, where corrosion starts
- Cable type and insulation where it is visible, and the condition of junction boxes
- Control: photocell on each head, a contactor cabinet with a timer, or a central system
- Road width and use: lanes, speed, pedestrians, junctions
The survey usually shows that most poles can stay. Replacing a sound pole adds cost without adding light. Where a few poles are corroded or leaning, budget for those individually.
Step 2: Decide the lighting class
A sodium road was often lit to whatever the lamp delivered. A retrofit is the moment to decide what the road actually needs. In EN 13201 terms a fast multi-lane road is typically M2 or M3; a residential street M4–M5. The class sets the target, and the target sets the wattage. Our guide to road lighting classes explains how the class is chosen.
Step 3: Size the LED at the existing spacing
This is where retrofits go wrong. “400 W HPS, so 200 W LED” is a guess; the correct method is to find the LED power that meets the class at the spacing you already have.
Take a road like this: a 15 m wide carriageway, 12 m poles, staggered layout, existing spacing 42 m. In our pole height and spacing calculator, with LED luminaires at 110 lm/W and a maintenance factor of 0.8:
| Target class | Average lux target | LED power needed at 42 m | Standard step |
|---|---|---|---|
| M3 | 15 lx | about 132 W | 150 W |
| M2 | 22 lx | about 194 W | 200 W |
Open the M2 example. A 200 W luminaire gives about 22.7 lx average at 42 m; a 150 W luminaire gives about 17 lx, comfortably above M3. Either way the old 400 W lamp is replaced by less than half its wattage, and the spacing does not change.
On our LDM30C modular street light, the 150 W and 200 W versions differ by one LED module and use the same 140° × 80° road optic, so the light pattern stays the same if the class is later raised.
Step 4: Work out the savings and payback
The LED retrofit savings calculator needs only a few inputs. For a 13 km road at 48 lights per km (staggered, 42 m), that is 624 lights. Changing each from 400 W HPS to 150 W LED, running 12 hours a night:
- Old system power: 460 W per point (400 W lamp + 15% ballast loss)
- Old energy: about 1,257,000 kWh a year
- LED energy: about 410,000 kWh a year
- Saving: about 847,000 kWh a year, 67%
- At USD 0.15/kWh: about USD 127,000 a year in energy, plus about USD 11,000 in lamp changes avoided (USD 20 per point a year for HPS against 2 for LED)
- CO₂: about 424 t a year at 0.5 kg/kWh
Open this example. The luminaire and installation costs in the example (USD 180 and 30 per point) are placeholders to show the method, not a quotation; enter your own. With those placeholders the payback is just under a year. Even if the real figures are double, it stays within about two years, which is why large sodium networks are being converted city by city.
Step 5: Plan the controls now
A retrofit is the cheapest time to add dimming. Two options are worth pricing:
- Fixed dimming profile in the driver, for example 100% until midnight and 50% until dawn. No extra hardware; the 150 W light above would then use about 465 kWh a year instead of 657.
- A socket for a node (NEMA 7-pin or Zhaga) so a remote monitoring system can be added later.
Details in our LED street light dimming controls guide. Keep the existing photocells if they work; they switch an LED driver just as well as a ballast.
Step 6: Install section by section
On a busy road, crews usually replace one section a night, from a bucket truck, with traffic management in place. Each change takes minutes when the bracket matches the arm: isolate, remove the old head, fit the new one, connect, set the tilt, test. Two things are worth doing while up there:
- Check the arm tilt. Sodium lanterns were often tilted 10–15° to throw light across the road. Road optics on LED heads are designed to be mounted flat or at a small tilt; too much tilt adds glare and sky glow.
- Replace the fuse and the cable tail to the head if they are old. It costs little and removes a common cause of later failures.
Common retrofit mistakes
- Copying the wattage ratio. Halving the old wattage may over-light a road or under-light it, depending on spacing. Calculate.
- Ignoring the colour change. Sodium is about 2000 K; LED at 4000 K looks very different. Many cities choose 3000 K for residential streets and 4000 K for main roads. Agree it before ordering.
- Forgetting the junctions. Junctions and crossings often need more light than the straight sections. Check them separately.
- No surge protection. Long overhead or buried runs see lightning surges that HPS ballasts shrugged off. Specify a surge protector of 10 kV or more in each head.
- Mixed optics. Using different luminaire families on one road gives patchy light. Keep one family and change the wattage.
What to ask a supplier
For a sodium-to-LED retrofit, ask for: a photometric calculation at your existing spacing, the luminaire lumens and efficacy from a test report, the bracket size and tilt range, driver dimming options, surge rating, and the warranty terms. If you are still deciding how far to go with the conversion, our HPS to LED conversion chart gives typical equivalents as a starting point, and metal halide vs high pressure sodium explains why the old lamps behave as they do.
Send us the road width, pole height, spacing and the old lamp wattage, and we will return a calculation and a set of LED street lights matched to the existing poles.
Sources
Frequently asked questions
What LED wattage replaces a 400 W high pressure sodium street light?
Usually 150–200 W, but the right answer depends on the road. At 12 m mounting height and 42 m spacing on a 15 m road, our calculator needs about 132 W at 110 lm/W for class M3 and about 194 W for M2. Run the calculation for your own road width and spacing.
Can I keep the existing poles when replacing HPS with LED?
In most cases, yes. If the poles, arms and foundations are sound, the LED heads are chosen to work at the existing spacing. Check the arm spigot diameter, the pole condition at ground level and the cable insulation before ordering.
How much energy does replacing HPS with LED save?
Typically 55–70%. A 400 W sodium lamp draws about 460 W with its ballast, so a 150 W LED uses about a third of that. Dimming late at night saves more.
Can I just put an LED bulb in a high pressure sodium fixture?
Yes, with an LED bulb made for it and the ballast bypassed, but it is a stop-gap. The old reflector was shaped for a sodium arc, so less light reaches the road and the bulb runs hot. For a road, a new LED head on the existing arm is the better conversion.
Do I need to change the photocell or controller?
Not always. Existing photocells and contactors usually work. If you want dimming or remote monitoring, specify LED drivers with a dimming input or a NEMA/Zhaga socket at the order stage, as it is cheap to add then and expensive later.