IEC 60079 Explained: Which Part Covers What When You Buy Explosion-Proof Lights
A buyer's map of the IEC 60079 explosion-proof standard series: which part covers each protection type, area classification and installation, and how GB 3836, ATEX and UL relate.
Key points
- IEC 60079 is a family of more than 30 parts: Part 0 sets general rules, and each protection type has its own part.
- For a typical explosion-proof LED light, the parts that matter are 0 (general), 1 (flameproof d), 7 (increased safety e), 18 (encapsulation m) and 31 (dust t).
- Area classification (Parts 10-1 and 10-2), installation (14) and inspection (17) are written for the site, not for the manufacturer.
- China's GB/T 3836, Europe's EN IEC 60079 and the US UL 60079 series are national adoptions of the same text, with local differences.
- Our BED series certificate lists GB/T 3836.1, .2, .3, .9 and .31, which match IEC 60079-0, -1, -7, -18 and -31.
When a tender for hazardous-area lighting says “to IEC 60079”, it does not name one document. It points to a family of standards, each covering a different part of the job. Some are for the manufacturer, some for the engineer who classifies the area and some for the electrician and the inspector. Knowing which part applies to which question saves time when you compare quotations and certificates. This guide is the map we use internally.
How the series is organised
The parts fall into four groups:
- Part 0: general requirements. Every certificate cites it. It sets the marking, temperature classes, materials, impact and drop tests, and ambient range rules.
- Protection-type parts. One part per method of protection, used together with Part 0.
- Site parts. Area classification, selection and installation, inspection and maintenance, repair.
- Supporting parts. Gas data, intrinsically safe systems, special cases.
Protection-type parts
| Part | Protection type | Code |
|---|---|---|
| 60079-1 | Flameproof enclosure | d |
| 60079-2 | Pressurised enclosure | p |
| 60079-5 | Powder filling | q |
| 60079-6 | Liquid immersion | o |
| 60079-7 | Increased safety | e |
| 60079-11 | Intrinsic safety | i |
| 60079-13 | Pressurised rooms | p (rooms) |
| 60079-15 | Type n (remaining methods) | n |
| 60079-18 | Encapsulation | m |
| 60079-28 | Optical radiation | op |
| 60079-31 | Dust ignition protection by enclosure | t |
| 60079-33 | Special protection | s |
A product’s marking tells you which of these parts it was tested to. If a label says “Ex db eb mb”, look for Parts 1, 7 and 18 on the certificate. Our guide on how to read an Ex marking decodes the letters.
Site parts
| Part | Subject | Who uses it |
|---|---|---|
| 60079-10-1 | Classification of gas areas into Zones 0, 1, 2 | Process safety engineer |
| 60079-10-2 | Classification of dust areas into Zones 20, 21, 22 | Process safety engineer |
| 60079-14 | Design, selection and erection of electrical installations | Electrical designer, installer |
| 60079-17 | Inspection and maintenance | Site maintenance team, inspector |
| 60079-19 | Repair, overhaul and reclamation | Repair workshop |
These parts decide which equipment is allowed where, how cables and glands are installed, and how often fittings are inspected. A light can be perfectly certified and still be installed wrongly. For example, Part 14 sets rules for cable entries and unused openings that apply regardless of the light’s own certificate.
Supporting parts
- 60079-20-1: gas and vapour data: ignition temperatures, gas groups, flammable limits. This is where the T class and group for each substance come from.
- 60079-25: intrinsically safe systems, for loops with several devices.
- 60079-26: equipment with EPL Ga, for Zone 0.
- 60079-29 series: gas detectors.
- 60079-35: caplights for mines.
The parts behind a typical LED explosion-proof light
Most modern LED fittings combine several methods in one body, because a single method is heavy or expensive. Our own BED series is a good example, because its certificate lists the standards it was tested to:
| On our certificate (GB/T 3836) | IEC equivalent | Part of the light it covers |
|---|---|---|
| GB/T 3836.1 | IEC 60079-0 | General: marking, materials, temperature, impact |
| GB/T 3836.2 | IEC 60079-1 | Flameproof LED chamber (db) |
| GB/T 3836.3 | IEC 60079-7 | Increased-safety terminal box (eb) |
| GB/T 3836.9 | IEC 60079-18 | Encapsulated driver (mb) |
| GB/T 3836.31 | IEC 60079-31 | Dust protection by enclosure (tb) |
The resulting marking is Ex db eb mb IIC T4 Gb for gas and Ex tb IIIC T130 °C Db for dust. The certificate number is ZJEx23.0914, valid to July 2028. It was issued in China under GB 3836. It is not an ATEX or IECEx certificate, and we state that in every quotation.
National adoptions of the same text
The IEC parts are adopted, sometimes with changes, by national and regional bodies:
| Region | Standard series | Certificate you will see |
|---|---|---|
| International | IEC 60079 | IECEx certificate of conformity |
| European Union | EN IEC 60079 (harmonised under ATEX) | EU-type examination certificate, ATEX marking |
| China | GB/T 3836 | Chinese Ex certificate (and CCC for some products) |
| United States | UL 60079 series, NEC Article 505 | UL or other NRTL listing for Zone-rated equipment |
| Canada | CSA C22.2 No. 60079 series | CSA or other certification |
The text is close, but the certificate is what an inspector checks. A product tested to GB/T 3836 meets the same technical rules as one tested to IEC 60079, edition for edition, yet a site that requires IECEx or ATEX will still ask for that certificate. Our article on who certifies explosion-proof lights lists the schemes and bodies.
Editions matter
Each part is revised every few years. Part 0, for instance, has had editions in 2011, 2017 and later. A certificate names the edition it was tested to. When a specification says “latest edition”, check whether the authority accepts certificates to the previous edition during the transition period. Most schemes allow a few years.
Two examples of changes that affect lights:
– The level letters (db, eb, mb) were added to protection codes in recent editions. A fitting certified earlier may show plain “d” or “e”.
– Type “nA” (non-sparking) moved into Part 7 as “ec”. A Zone 2 fitting described as “Ex nA” on an old data sheet would now be marked “Ex ec”.
Testing under Part 1: what a flameproof light goes through
For the flameproof part, the main tests are:
- Reference pressure: the gas mixture is ignited inside the enclosure to find the peak explosion pressure.
- Overpressure test: the enclosure must withstand 1.5 times the reference pressure (or a higher static test) without damage.
- Non-transmission test: an internal explosion must not ignite the gas surrounding the enclosure through its flamepaths.
- Thermal tests: the hottest surface at maximum ambient sets the T class.
Our article on explosion-proof light testing covers these and the impact, ingress and thermal endurance tests in Part 0. For increased safety under Part 7, see Ex eb increased safety.
What to put in your tender
A clear specification names three things: the zone and group from Part 10-1 or 10-2, the required certificate scheme (IECEx, ATEX, national), and the inspection rules under Part 17 that the site follows. Send us those three lines and we will reply with the fittings that match and the exact standards and editions on their certificates.
Sources
Frequently asked questions
What is IEC 60079?
It is the international standard series for equipment and installations in explosive atmospheres. Part 0 sets the general requirements, other parts cover each protection method, and some parts cover area classification, installation, inspection and repair.
Which IEC 60079 part covers explosion-proof (flameproof) lights?
Flameproof enclosures, protection type d, are covered by IEC 60079-1, always together with the general requirements in IEC 60079-0. Most LED fittings also use Part 7 (increased safety) for the terminal box and Part 18 (encapsulation) for the driver.
Is GB 3836 the same as IEC 60079?
GB/T 3836 is China's adoption of IEC 60079, part by part. The technical content is largely the same, but a GB 3836 certificate is a Chinese certificate. It is not an IECEx or ATEX certificate.
Which part covers dust?
IEC 60079-31 covers dust ignition protection by enclosure, protection type t. Dust area classification is in IEC 60079-10-2.