What an IES or LDT file contains, how lighting software uses it, what to check before trusting one, and when a quick calculator is enough instead of a full DIALux study.

Key points

  • An IES file (IES LM-63) or LDT file (EULUMDAT) describes how much light a luminaire sends in every direction, measured in a goniophotometer.
  • Lighting software such as DIALux, Relux and AGi32 uses these files to calculate lux, uniformity and glare for a real layout.
  • Check that the file matches the exact model, wattage, optic and colour temperature in your quotation; a file for a different optic gives a wrong design.
  • For early sizing, a calculator based on lumens and utilisation factor gets within the right range; for tenders and sports or road projects, use the photometric file.

When a project moves from “roughly how many lights?” to a tender or a design for approval, someone will ask for the IES files. Many buyers have heard the term but never opened one. This guide explains what is inside a photometric file, how designers use it, what can go wrong, and when a simpler calculation is enough.

What a photometric file is

A luminaire’s light is not uniform in all directions. A road light throws light along the road and keeps it off the houses behind; a narrow floodlight concentrates it in a tight cone. To describe this, the luminaire is measured in a goniophotometer, which records the light intensity (in candelas) at many angles around it.

The results are saved in one of two standard text formats:

  • IES LM-63 (.ies), defined by the Illuminating Engineering Society and common in North America and much of Asia.
  • EULUMDAT (.ldt), common in Europe.

Both contain essentially the same information, and design programs read both.

What is inside

A typical file includes:

Field What it tells you
Manufacturer, catalogue number, test lab and date Which luminaire was measured and when
Luminaire lumens and input watts Output and efficacy
Luminous dimensions Size of the light-emitting area, used for glare and luminance
Angle grid The vertical and horizontal angles measured
Candela table Intensity at every angle on the grid

From the candela table, software can draw the polar curve (the familiar butterfly or cone shape), calculate the beam and field angles, and work out how much light lands on any point of a road, floor or pitch.

How designers use it

In DIALux, Relux or AGi32, the designer builds the space (room, road, pitch or yard), places luminaires from their photometric files at the planned heights and aiming angles, and sets surface reflectances and a maintenance factor. The software then calculates:

  • average and minimum illuminance, and uniformity;
  • luminance and threshold increment for roads;
  • UGR for interiors (see what is UGR);
  • vertical illuminance for sports and cameras;
  • light spill and obtrusive light near boundaries.

The result is a report that authorities, consultants and sports federations can check, which a simple wattage list cannot provide.

What to check before trusting a file

We regularly see designs that fail on site because the file did not match the product delivered. Check:

  1. Exact model and wattage. A 150 W file scaled down to 100 W is not the same as a measured 100 W file.
  2. The optic. Road lights and floodlights come with several lenses. The file for a 140° × 80° road optic tells you nothing about a symmetric 120° lens. Our BG-TZ-M sports floodlight, for example, has asymmetric 140° × 80° and 155° × 80° optics, which light a court very differently.
  3. Colour temperature and CRI. Higher CRI and warmer colour usually mean fewer lumens. A file measured at 5000 K Ra 70 overstates a 3000 K Ra 80 version.
  4. Lab and date. An old test of a previous LED generation may overstate or understate the current product.
  5. Lumens and watts make sense. Divide one by the other and compare with the datasheet efficacy.

When a calculator is enough

Full photometric design takes time. For early budgeting or checking a quotation, a lumen-method calculation is often enough to know whether 20 or 40 lights are needed. Our calculators do this:

They do not replace a photometric study for uniformity, glare and spill, but they are close enough to tell whether a design or a quotation is in the right range. If a quotation proposes half or double the number of fittings the calculator suggests for the same target, that is the moment to ask for the photometric study behind it.

Common mistakes with photometric files

  • Mixing maintenance factors. One design at MF 0.9, another at 0.7; the first looks 30% better on paper.
  • Wrong mounting height or tilt. A road light tilted 10° in the model but mounted flat on site gives a different result.
  • Missing obstructions. Racks, trees and roof beams block light; models without them flatter the design.
  • Ignoring the file’s luminous dimensions when assessing glare.

What to ask a supplier for

  • IES or LDT files for the exact model, wattage, optic and colour temperature quoted.
  • The test report or at least the lab name and date.
  • For sports and road projects, a lighting calculation report with the files used, so your consultant can check it.

Summary

An IES or LDT file is the luminaire’s light distribution in a form software can use. It turns a product into a design: lux, uniformity, glare and spill for your real space. Make sure the file matches exactly what you are buying, use the same assumptions when comparing designs, and use a quick calculator for early sizing before you commission a full study.

Sources

  1. IES LM-63 Standard file format for electronic transfer of photometric data
  2. EULUMDAT file format description
  3. DIALux — free lighting design software

Frequently asked questions

What is an IES file?

A text file in the IES LM-63 format that lists a luminaire's light intensity, in candelas, at many angles around it, plus its lumens, dimensions and wattage. Lighting software reads it to model how the luminaire will light a space.

What is the difference between IES and LDT files?

They hold the same kind of data. IES (LM-63) is the North American format; LDT (EULUMDAT) is common in Europe. DIALux and Relux read both.

Can I open an IES file without lighting software?

Yes, it is plain text, but the numbers are hard to read. Free viewers show the polar curve and key values, and DIALux is free to download.

Why does my DIALux result differ from the supplier's calculator?

Usually because of different maintenance factors, reflectances, mounting heights or a file for a different optic. Make sure both use the same inputs before comparing results.

Products in this guide

Have a project?

Ask our engineers

Send us your site details and we will size the system and quote it.

We reply by email within one working day (China time, GMT+8). Your details are only used to answer this inquiry. Prefer chat? Message us on WhatsApp. Have more detail to give? Use the full form.