ATEX IIB vs IIC: Gas Groups for Explosion-Proof Lights and How to Choose

IIB vs IIC in plain terms: IIC covers hydrogen and acetylene, IIB ethylene, IIA propane. Flame-gap limits, NEC group equivalents, IIB+H2 and how to choose.

Key points

  • Gas groups rank gases by how easily a flame passes through a narrow gap: IIA is the least demanding, IIC the most.
  • IIC covers hydrogen and acetylene; IIB covers ethylene and similar gases; IIA covers propane, petrol and most solvents.
  • A IIC light may be used in IIB and IIA areas. A IIB light may not be used where hydrogen or acetylene can be present, unless it is marked IIB+H2.
  • The safe flame gap for IIC is below 0.5 mm, against 0.5–0.9 mm for IIB, so IIC flameproof housings need tighter joints.
  • NEC groups run the other way: Group A is acetylene, B hydrogen, C ethylene and D propane.

In an explosion-proof marking such as Ex db IIC T4 Gb, the letters IIC are the gas group. They tell you which gases the light has been tested with. The difference between IIB and IIC is the difference between a light that is safe around hydrogen and one that is not. This guide explains the three groups, how they are defined, and how to choose.

Group I and Group II

Explosion-protected equipment is divided first by where it is used:

  • Group I: mines where firedamp (methane) may be present;
  • Group II: surface industry with explosive gases;
  • Group III: explosive dusts.

Group II is then split into IIA, IIB and IIC. The split exists because gases behave very differently once they are burning inside a housing.

IIA, IIB and IIC at a glance

Group Typical gases Maximum experimental safe gap Minimum igniting current ratio
IIA Propane, butane, petrol, diesel, acetone, ammonia, most solvents above 0.9 mm above 0.8
IIB Ethylene, ethyl ether, town gas 0.5–0.9 mm 0.45–0.8
IIC Hydrogen, acetylene, carbon disulphide below 0.5 mm below 0.45

Two laboratory measurements place a gas in its group.

The maximum experimental safe gap is found by igniting the gas inside a test chamber and measuring the widest joint, 25 mm long, through which the flame fails to light the same gas outside. Hydrogen flames pass through gaps that would stop a propane flame easily.

The minimum igniting current ratio compares the current needed to ignite the gas with the current needed for methane. It matters most for intrinsically safe circuits, where the energy of a spark is limited.

Why the group changes the light

Most explosion-proof lights use a flameproof housing, protection type “d”. The idea is that gas may enter the housing and may even ignite there, but the housing holds the pressure and the joints cool the escaping flame so that it cannot light the gas outside. Our article on explosion-proof vs flameproof describes the principle.

For a flameproof housing, the gas group therefore sets:

  • the maximum gap and minimum length of every joint: threads, flanges, the glass seat and the cable entries;
  • the test pressure the housing must withstand, since hydrogen and acetylene give higher and faster pressure rises;
  • the machining quality and so the cost.

A IIC flameproof housing has longer, tighter joints than a IIB one, and often uses threaded covers instead of flat flanges. For increased-safety “e” and encapsulated “m” parts, the gas group makes little difference to the construction, which is why many modern LED lights combine several protection types.

The hierarchy

Light marked May be used with IIA gases IIB gases IIC gases
IIA Yes No No
IIB Yes Yes No
IIB+H2 Yes Yes Hydrogen only
IIC Yes Yes Yes

IIB+H2 is a common marking on large flameproof enclosures. It means the housing passed the tests for hydrogen but not for acetylene. It is acceptable in hydrogen areas such as battery rooms and electrolyser plants, and not acceptable where acetylene is present.

Where each group turns up

Site Typical gas Group needed
Petrol stations, fuel depots Petrol vapour IIA
LPG filling plants Propane, butane IIA
Paint shops and solvent stores Acetone, toluene, xylene IIA
Petrochemical plants Ethylene and mixed streams IIB, sometimes IIC
Refinery hydrogen units Hydrogen IIC or IIB+H2
Battery charging rooms Hydrogen IIC or IIB+H2
Electrolysers and hydrogen filling Hydrogen IIC or IIB+H2
Welding gas stores Acetylene IIC

The area classification of the site names the group. If several gases are possible, the most demanding one decides.

NEC groups: the letters run the other way

North American Class I groups cover the same gases with different letters:

IEC and ATEX NEC Class I Reference gas
IIC Group A Acetylene
IIC Group B Hydrogen
IIB Group C Ethylene
IIA Group D Propane

Because the order is reversed, “Group A” is the most demanding in the NEC and “IIA” is the least demanding in the IEC system. It is one of the most common mix-ups on enquiries. Our guide to Class 1 Division 1 explosion-proof lighting covers the North American side.

A real IIC marking

Our BED explosion-proof LED light is certified Ex db eb mb IIC T4 Gb under certificate ZJEx23.0914, valid from 11 July 2023 to 10 July 2028. Reading it:

  • db, eb, mb: flameproof, increased-safety and encapsulated parts in one light;
  • IIC: tested for the most demanding gas group, so it also covers IIB and IIA;
  • T4: no surface above 135 °C;
  • Gb: equipment protection level for Zone 1, and so also Zone 2.

The series covers 30 W to 600 W on AC 220 V with IP65 protection. A second marking, Ex tb IIIC T130 °C Db, covers dust. Dust has its own groups: IIIA for combustible flyings, IIIB for non-conductive dust and IIIC for conductive dust, with IIIC the most demanding.

This certificate is for the BED series. For other series we confirm the marking and the certificate with the quotation.

How to choose

  1. Read the gas group from the area classification. Do not guess from the industry.
  2. If hydrogen or acetylene is listed, you need IIC, or IIB+H2 for hydrogen only.
  3. Otherwise IIB covers most petrochemical streams and IIA covers fuels and solvents.
  4. A higher group is always acceptable. It costs a little more and simplifies spares if one plant has several areas.
  5. Then check the temperature class, the zone and the ambient temperature separately. The gas group says nothing about them: hydrogen is IIC but only needs T1.

For the other parts of the marking, see explosion-proof light ratings explained.

Common mistakes

Mistake Result
Reading “Group A” and “IIA” as the same A light for the least demanding gases ordered for acetylene
Using plain IIB lights in a battery room Not covered for hydrogen
Assuming IIC also means a strict temperature class The T class is a separate rating
Using a gas-group marking in a dust area Dust needs a Group III marking
Replacing cable glands with uncertified ones The entry is no longer flameproof for the group

Installation points that depend on the group

  • Do not damage or paint the flame joints, and do not add gaskets that are not part of the design.
  • Use cable glands and blanking plugs certified for the same group, or a higher one.
  • Keep the specified clearance between a flanged joint and any solid obstacle. The distance grows from IIA to IIC.
  • Tighten every cover bolt. A missing bolt opens the gap.

Ordering

Send the zone, gas group, temperature class, supply voltage and mounting height. If the site lists hydrogen or acetylene, say so in the enquiry and we will quote a IIC light with its certificate.

Sources

  1. IEC 60079-20-1 — Material characteristics for gas and vapour classification
  2. IEC 60079-1 — Equipment protection by flameproof enclosures 'd'
  3. NFPA 70 — National Electrical Code, Article 500 (groups A to G)

Frequently asked questions

What is the difference between IIB and IIC?

They are gas groups. IIC is for the gases that are easiest to ignite through a small gap, mainly hydrogen and acetylene. IIB is for ethylene and gases of similar behaviour. Equipment marked IIC meets the tighter limits and also covers IIB and IIA.

Can I use a IIB light in a hydrogen area?

No, not a plain IIB light. Hydrogen is a IIC gas. Use a IIC light, or one specifically marked IIB+H2, which has been tested for hydrogen but not for acetylene.

Is IIC the same as NEC Group A?

Not exactly. IIC covers both acetylene and hydrogen. In the NEC, acetylene is Group A and hydrogen is Group B. IIB corresponds roughly to Group C and IIA to Group D.

Do I need IIC for a petrol station?

Petrol vapour is a IIA gas, so IIA is the minimum. Many lights are certified IIB or IIC anyway, and those are acceptable because the higher group includes the lower ones.

What does IIB+H2 mean?

It is a IIB marking extended to hydrogen: the equipment passed the IIB tests and the tests for hydrogen, but not for acetylene. It may be used with IIA and IIB gases and in hydrogen areas such as battery rooms and electrolyser plants, but not where acetylene can be present.